| Photoluminescent exit signs |
|
Efficiency requirements:
- UL 294 compliance
- 90 minutes of back-up light
- Cannot require input or backup battery power
|
$20 |
| Compact fluorescent fixtures |
|
| Eligible unit shall consist of an electronic ballast and compact fluorescent lamp. Ballasts must be certified by a nationally recognized testing laboratory (NRTL). All fixtures must be hard-wired. |
|
| CF 7 to 26-Watts hard-wired |
$25 |
| CF 27 to 55-Watts hard-wired |
$35 |
| CF 56 to 99-Watts hard-wired |
$45 |
| Cold cathode fluorescent lamps |
|
| Eligible units shall consist of cold cathode fluorescent lamps that are not used with digital dimming systems. They will be certified by a nationally recognized testing laboratory, have a minimum 2 year warranty and have a hard-wired fixture. |
|
| 3 Watt |
$4 |
| 5 Watt |
$4 |
| 8 Watt |
$4 |
| 13 Watt |
$4 |
| 18 Watt |
$4 |
| High-efficiency fluorescent fixtures (T8 or T5) |
|
| Recessed or surface-mounted fixture with electronic ballast. Each eligible unit shall consist of a ballast and not more than 2 lamps, or a low-power ballast (ballast factor less than 0.80) for more than 2 lamps. Overall luminaire efficiency shall exceed 72% for parabolic fixtures or open-bottom luminaires, and 80% for prismatic lensed luminaires. Luminaire efficiency shall be tested per IES standards. |
|
| High-efficiency 1-lamp T8 or T5 fixture |
$10 |
| High-efficiency 2-lamp T8 or T5 fixture |
$10 |
| High-efficiency 3-lamp T8 or T5 fixture |
$10 |
| High-efficiency 4-lamp T8 or T5 fixture |
$10 |
High performance T8 fluorescent fixtures (super, ultimate, ultra, extreme) |
|
| Fixtures with high performance electronic ballasts and T8 lamps only. Each eligible unit shall consist of a ballast and not more than four lamps. The lamp/ballast combination shall have a maintained efficacy of 90 lumens per watt (mean lumens/ lamp nominal watts). |
|
| High performance 1-lamp T8 fixture |
$20 |
| High performance 2-lamp T8 fixture |
$20 |
| High performance 3-lamp T8 fixture |
$20 |
| High performance 4-lamp T8 fixture |
$20 |
| High-efficiency pendent & wall mounted indirect fluorescent fixtures |
|
| Each eligible unit shall consist of a four-foot section containing not more than 3 lamps, with an indirect or indirect/direct light distribution. Overall fixture efficiency shall exceed 77%. |
|
| T8 lamps with electronic ballast per 4 ft. section |
$14 |
| T5 lamps with electronic ballast per 4 ft. section |
$20 |
| High bay T8 or T5 fixtures |
|
| Each eligible unit shall have three or more lamps for T5 fixtures, and four or more lamps for T8 fixtures. Fixture must be installed in a high bay area with a minimum ceiling height of 15 ft. Overall fixture efficiency shall exceed 81% for T8 fixtures and 88% for T5 fixtures. |
|
| T8 or T5 lamps with electronic ballast |
$35 |
| Bi-Level Lighting |
|
| Each eligible unit shall consist of a four-foot section containing two T8 or T5 lamps, with an integrated occupancy sensor and dimming ballast capable of at least 50% Wattage reduction. Units must be installed in a restroom, stairwell, or emergency egress corridor. Units required by code are not eligible. |
|
| Bi-level lighting per 4 foot section |
$26 |
| Fluorescent controls |
|
| Each eligible unit shall be hard-wired and use passive infrared and/or ultrasonic technology, or two-technology. Unit must control a minimum of 100 Watts. All units with manual "ON" overrides are not eligible. Units required by code are not eligible. (Note 1) |
|
| Occupancy sensors (wall mounted) |
$75 |
| Occupancy sensors (ceiling mounted) |
$75 |
| Occupancy sensors (fixture mounted) |
$50 |
| Occupancy sensors (wall switch) |
$25 |
| Each eligible unit shall contain a photo sensor that controls a minimum of 200 Watts. All units with manual "ON" overrides are not eligible. Units required by code are not eligible. (Note 2) |
|
| Daylight controlled dimming |
$100 |
| Each eligible unit shall control fluorescent fixtures based on occupancy, and must control a minimum of 200 Watts. Ballast power consumption in 'Low' mode must not exceed 50% of full load. All units with manual "ON" overrides are not eligible. Units required by code are not eligible. (Note 1) |
|
| Occupancy controlled hi-low switching |
$60 |
| HID controls |
|
| Each eligible unit shall control HID fixtures based on occupancy, and must control a minimum of 700 Watts. All units with manual "ON" overrides are not eligible. Units required by code are not eligible. (Note 1) |
|
| Occupancy controlled hi-low switching |
$75 |
| Each eligible unit shall contain a photo sensor that controls a minimum of 700 Watts. All units with manual "ON" overrides are not eligible. Units required by code are not eligible. (Note 2) |
|
| Daylight controlled dimming |
$100 |
| LED Refrigerator Case Lighting |
|
| Each eligible unit shall consist of a low or medium temperature case operating 18 or 24 hours per day. Unit must be permanently installed with an electronic ballast. |
|
| LED refrigeration case lighting (per linear foot-width) |
$30 |